最近中文字幕在线mv视频在线,中文字幕无码家庭乱欲,一区二区伊人久久大杳蕉 ,亚洲综合国产一区,夜夜爽www

產(chǎn)品簡介
供應 ABB S503HV-K20 3P 20A 1000V
供應 ABB S503HV-K20 3P 20A 1000V
產(chǎn)品價格:¥1
上架日期:2017-09-26 16:05:32
產(chǎn)地:S503HV-K20 3P 20A 1000V
發(fā)貨地:廈門
供應數(shù)量:不限
最少起訂:1個
瀏覽量:181
資料下載:點擊下載
其他下載:暫無相關下載
詳細說明
    MicroVersaTrip? Plus and PM trip units.
    System Requirements Product List Price
    Debion (price separaby) Number G0-104A
    1.5 ampere power supply
    Price one PLPS4G01 for
    each line-up. 45 trip units Input power, 100VA
    and 100 ft. maximum. (85-265Vac or 100-370Vdc) PLPS4G01 緯軒機電1250.00
    POWER LEADER? Voltage Conditioner
    Conditions and scales 120Vac to 1.76 Vac for use by the trip unit
    for voltage sensing. Provides transient protection. Voltage conditioners
    require isolation PTs.
    System Requirements Product List Price
    Debion (price separaby) Number G0-104A
    Supplies isolated bus
    voltage signal to One set of 3 voltage conditioners
    MicroVersaTrip? PM required for each voltage sensing 緯軒機電200.00
    trip units. b. PTs also required. PLVC1G01 per set
    Neutral Current Sensors1
    Circuit Breaker Neutral Sensor
    Breaker Frame Sensor Rating Rating or Tap Product List Price
    (Amperes) (Amperes) Settings (Amperes) Number GO-245B
    200 200 TSVG302 緯軒機電266.00
    800 400 400/200 TSVG304A 緯軒機電266.00
    400 600/3002 TSVG306A 緯軒機電266.00
    800-1600 800 800/400 TSVG308A 緯軒機電266.00
    1000 800/4002 TSVG808A 緯軒機電266.00
    1600 1000 1000/500 TSVG810A 緯軒機電266.00
    1600 1200/6002 TSVG812A 緯軒機電266.00
    1600 1600/1000 TSVG816A 緯軒機電266.00
    2000 2000 2000/1000 TSVG820A 緯軒機電266.00
    1000 800/4002 TSVG808A 緯軒機電266.00
    1000 1000/500 TSVG810A 緯軒機電266.00
    1000 1200/6002 TSVG812A 緯軒機電266.00
    3000 1000 1600/10002 TSVG816A 緯軒機電266.00
    2000 2000/1200 TSVG820A 緯軒機電266.00
    2500 2500/1800 TSVG825A 緯軒機電266.00
    3000 3000/2400 TSVG830A 緯軒機電266.00
    4000 4000 4000/3000 TSVG940A 緯軒機電266.00
    1Match neutral current sensor rating (or tap setting) to circuit breaker sensor rating.
    2For use with multiple source ground fault protection schemes. Rating does not
    match MicroVersaTrip? Plus or PM frame sensor.
    Neutral Current Sensor
    Rating Plug Removal Tool
    List Price
    Product Number GO-135S
    TRTOOL 緯軒機電12.00
    Reference
    Instructions GEH-6492
    Reference
    Instructions GEH-5946
    Insulated Case Circuit Breakers
    Power Break? II Circuit Breaker Accessories
    Neutral Current Sensors and POWER LEADER Accessories
    Components: Parts
    1
    1-30 Aftermarket Catalog www.geelectrical.com Prices and data subject
    to change without notice
    Features
    —Draw-outs through 4000 amperes are UL Listed, 100% rated
    —Modular design for simplified installation—6 basic sizes—800, 1600, 2000, 2500,
    3000, 4000—5 inch pole centers
    —Screw racking mechanism provides positive racking motion
    —Self aligning primary and secondary disconnects
    —Four b draw-out—engaged, test, disengaged, fully withdrawn—
    simplifies system testing and inspection
    —Breaker b indicator bly shows breaker b
    —Provisions for padlocking breaker in test or disengaged b
    —Mechanical interlock logic prevents movement of a closed breaker
    —Suitable for reverse feeding
    Debion
    The draw-out assembly consists of a substructure housing unit designed as a compact
    self-supporting unit and a draw-out breaker which must be ordered separaby. The
    substructure contains mounting holes, self-supporting male plugs and extendable rails,
    and can be ordered separaby for installation in your switchboard or enclosure.
    The Power Break? II draw-out breaker is a self-contained, heavy-duty assembly designed
    to offer simplified breaker inspection without de-energizing the main bus structure.
    The draw-out breaker comes complete with racking mechanism drive, wheels, primary
    and secondary disconnects and cooperating interlock systems.
    Accessories such as dead-front shutters, by-pass switches (b switches), and
    padlock devices are available and field installable.
    OEM Substructures
    Substructures are available for both standard and Hi-Break Power Break? II breakers.
    Holes are provided for bolting on a shelf or supports. Holes are also provided in the primary
    stabs for bolting to busbars or terminal lugs. Substructure secondary disconnects
    are ordered and priced separaby. Order Hi-Break substructures for use with Power
    Break? II switches.
    Frame Rating Standard Break List Price Hi-Break List Price
    (Amperes) Product Number GO-245B Product Number GO-245B
    800 SPSDOS08 緯軒機電671.00 SPHDOS08 緯軒機電724.00
    1600 SPSDOS16 緯軒機電1300.00 SPHDOS16 緯軒機電1403.00
    2000 SPSDOS20 緯軒機電1892.00 SPHDOS20 緯軒機電2040.00
    2500 SPSDOS25 緯軒機電2048.00 SPHDOS25 緯軒機電2207.00
    3000 SPSDOS30 緯軒機電2739.00 SPHDOS30 緯軒機電2951.00
    4000 SPSDOS40 緯軒機電6916.00 SPHDOS40 緯軒機電7455.00
    List Price
    Location Product Number GO-245B
    Substructure SPDOSD36S 緯軒機電283.00
    Breaker1 SPDOSD36B 緯軒機電283.00
    1Order for replacement only. Included and factory wired with draw-out breaker.
    Draw-out Breaker in Substructure
    1600-ampere substructure for
    standard break breaker
    Secondary Disconnect for Draw-out Breakers
    Control wiring is connected through draw-out secondary disconnects in the "TEST" and
     "CONNECTED" bs only. Up to 72 control circuits are possible through 36 b
    plug-style secondary disconnect blocks factory mounted to each side of draw-out
    breakers. One substructure disconnect (SPDOSD36S) must be ordered for each breaker
    when accessories or communications are used. When auxiliary switches are used along
    with any other electrical accessory or communications, two disconnects must be ordered.
    Insulated Case Circuit Breakers
    Power Break? II Circuit Breaker Accessories
    Draw-out Breaker Accessories
    Components: Parts
    1
    Prices and data subject Aftermarket Catalog www.geelectrical.com 1-31
    to change without notice
    Racking Tool
    The racking tool is a drive wrench with a square 1/2" socket
    that engages the racking mechanism of the draw-out breaker.
    One racking tool is supplied with every five draw-out breakers
    at no charge.
    List Price
    Frame Rating Product Number GO-245B
    All TDORT 緯軒機電70.00
    Mechanical Interlocks
    Mechanical interlocks provide the same function as the walking
    beam accessory for stationary breakers, except they are used
    with two draw-out breakers: mounted on common compartment
    centerline, in either the same vertical section or adjacent vertical
    sections.
    List Price
    Envelope Size Product Number GO-245B
    800-2000 SPDOWB20 緯軒機電1310.00
    2500-4000 SPDOWB40 緯軒機電1310.00
    Rail Kit
    This field installable rail kit may be used to shorten the two
    standard OEM substructure rails by 3-1/2 inches.
    List Price
    Product Number GO-245B
    SPRAILS 緯軒機電310.00
    Position Switch
    Provides positive indication when the draw-out breaker or switch
    primary contact fingers have been fully withdrawn from the main
    bus connections. Switch contacts change state only after the
    primary fingers are fully disconnected when the breaker is being
    moved from the CONNECTED b through the TEST b
    and into the DISCONNECTED b.
    May be used as part of a safety interlocking system in addition
    to the visual indicator on the draw-out substructure. The Position
    Switch accessory does not indicate either the TEST or CONNECTED
    b. The switch assembly mounts on the stationary frame
    and the actuator mounts to the carriage. Switch contacts are
    rated at 10A at 600 Vac, 0.75A at 125 Vdc, and 0.25A at 250 Vdc.
    Number of List Price
    Switch Elements Product Number GO-245B
    2 NO/2 NC SDOPS2L 緯軒機電177.00
    4 NO/4 NC SDOPS4L 緯軒機電256.00
    6 NO/6 NC SDOPS6L 緯軒機電336.00
    Shutter Kit
    This field installable kit provides shutters used to prevent unintentional
    contact with potentially live primary disconnect stabs when
    a breaker is racked out of an energized switchboard compartment.
    List Price
    Frame Rating Product Number GO-245B
    800-2000A SPDSS20 緯軒機電501.00
    3000A SPDSS30 緯軒機電501.00
    4000A SPDSS40 緯軒機電501.00
    By-Pass Switch
    Provides positive indication that the draw-out breaker or switch
     primary contact fingers are fully connected to the main bus in the
    substructure. Switch contacts change states only after the primary
    fingers are fully connected when the breaker is being
    moved from the DISCONNECTED b through the TEST b
    and into the CONNECTED b.
    May be used to provide control circuit continuity or downstream
     signaling that the draw-out breaker is connected in addition to
    the visual b indicator on the draw-out substructure. The
    By-pass switch accessory does not indicate either the TEST or
    DISCONNECTED b. The switch assembly mounts on the stationary
    frame and the actuator mounts to the carriage. Switch
    contacts are rated at 10A at 600 Vac, 0.75A at 125 Vdc, and
    0.25A at 250 Vdc.
    Number of List Price
    Switch Elements Product Number GO-245B
    2 NO/2 NC TDOBP2L 緯軒機電177.00
    4 NO/4 NC TDOBP4L 緯軒機電256.00
    6 NO/6 NC TDOBP6L 緯軒機電336.00
    Racking Padlock Provision
    The racking padlock provides a means for the user to prevent racking
    tool engagement, thereby preventing movement of the breaker
    between the DISCONNECTED, TEST and CONNECTED bs.
    List Price
    Frame Rating Product Number GO-245B
    All TDOPC 緯軒機電46.00
    Lifting Bar
    The lifting bar provides a means of safely lifting a draw-out circuit
    breaker. A chain hook can be attached to the central hole in the
    lifting bar or a 1" diameter black iron pipe can be put through the
    two holes above the hooks, allowing two people to carry the
    breaker below waist level from either side of the breaker.
    One lifting bar is supplied with every five draw-out breakers at
    no charge.
    List Price
    Frame Rating Product Number GO-245B
    All TDOLB 緯軒機電104.00
    Insulated Case Circuit Breakers
    Power Break? II Circuit Breaker Accessories
    Draw-out Breakers and Accessories
    All devices UL Listed for factory or field installation except where noted.
    Components: Parts
    1
    1-32 Aftermarket Catalog www.geelectrical.com Prices and data subject
    to change without notice
    Neutral Current (800: 1 ratio) Sensors
    Inside Core Thermal Rating Weight Product List Price
    Dimensions Construction (Amperes) (Lbs.) Number GO-142
    2.5” Dia. Solid 1600 3 TGS0002 緯軒機電460.00
    5” Dia. Solid 2500 4 TGS0005 緯軒機電731.00
    8” Dia. Solid 3000 7 TGS0008 緯軒機電856.00
    4” x 8” Split 4000 15 TGS0408 緯軒機電1439.00
    8” x 8” Split 4000 25 TGS0808 緯軒機電1482.00
    Neutral Current Sensor - Solid
    Neutral Current Sensor - Split
    Disconnect Switches and Operating Mechanisms
    High-Pressure Contact Switch
    With Integral Ground Fault Devices, 800-4000 Amperes, 600 Vac Max., UL File. No. E-51827
    Components: Parts
    1
    Prices and data subject Aftermarket Catalog www.geelectrical.com 1-33
    to change without notice
    Field Installed Lugs Kits 800-1600 Ampere
    Switches–Direct Mounting
    Field installed only. Kits consist of lugs and hardware for direct
     mounting to switch terminal straps (multiple-hole tang lugs) or lugs
    for mounting to 800 ampere terminal adapter kit. Order three kits
    for three-pole line or load end. For 1600-ampere, copper conductors
    must be used.
    Ampere Rating Accessory Wire Range Product List Price
    Type Cu/Al Number GO-145A
    800A Lug Kit Line (3) 300-750 THPCLUG308 緯軒機電63.50 & Lug Kit Load
    1200A, 1600A Lug Kit Line (4) 500-800 kcmil TPLUG408 緯軒機電39.001
    1200A, 1600A Lug Kit Load (4) 500-800 kcmil THPCLUG408 緯軒機電77.50
    1GO-245B
    Field Installed Lugs Kits 2000-4000 Ampere
    Switches–Direct Mounting
    Field installed only. To terminate line and load cables, must be
    used in conjunction with bus-connection adapter on page 7-20 (T
    Studs). Each lug kit includes lugs, straps and hardware for threephase
    line or load connections. Each cable lug accommodates
    1–3/0 Cu or 250 kcmil Al to 800 kcmil Cu-Al. Accepts Anderson
    VersaCrimp when lugs are removed from straps.
    No. of Lugs per Pole Product List Price
    Ampere Rating Line or Load End Number GO-245B
    2000A 6 TSLUG20 緯軒機電383.00
    2500A 7 TSLUG25 緯軒機電418.00
    3000A 9 TSLUG30 緯軒機電630.00
    4000A 11 TSLUG40 緯軒機電1045.00
    Field Installed T Studs
    Field installed only. May be used to adapt line and load terminals
    of switch to vertical or horizontal bus arrangements. Three
    required for line or load connections on three-phase bus. Accepts
    either lugs, bolts, or Anderson VCEL VersaCrimp.
    Basic Switch Product List Price
    Rating (Amperes) Number GO-145A
    800 THPC08FCA2 緯軒機電71.00
    1200-1600 TP16FCA 緯軒機電113.00
    2000 TS20FCA 緯軒機電113.00
    2500 TS25FCA 緯軒機電119.00
    3000 TS30FCA 緯軒機電418.00
    4000 (5)TS40FCA 緯軒機電562.00
    4000 (1)TS40LFCA3 緯軒機電789.00
    2For vertical bussing only.
    3For center pole, line terminal.
    Disconnect Switches and Operating Mechanisms
    High-Pressure Contact Switch
    Accessories, UL Listed
    Section 2: Switchgear
    Table of Contents
    Switchgear
    2
    Prices and data subject Aftermarket Catalog www.geelectrical.com 2-1
    to change without notice
    History/Timeline .............................................................................2-2
    Low Voltage Power and DC Circuit Breakers .............................2-3
    Gerapid High Speed DC Circuit Breakers ..........................................2-3
    AK and AKR Low Voltage Power
    Circuit Breakers.........................................................................................2-4
    Trip Unit Conversion Kits...........................................................................2-5
    Overview – EnbliGuard? TU and ProTrip?
    Conversion Kits.....................................................................................2-5
    ProTrip? Trip Unit Conversion Kits Selection Guide ...............2-7
    ProTrip? Rating Plugs.........................................................................2-11
    EnbliGuard? TU Trip Unit Conversion
    Kits Selection Guide.........................................................................2-12
    EnbliGuard? TU Trip Rating Plugs................................................2-16
    EnbliGuard? TU Trip Unit Conversion Kit
    Accessories and Hardware..........................................................2-17
    Trip Unit Conversion Kit Accessories ...........................................2-18
    Electrically Operated Racking Device .............................................2-20
    Technical Specifications.....................................................................2-21
    Reference Publications............................................................................2-22
    Asbestos Free Arc Quencher Replacement Kits..........................2-23
    This catalog contains replacement parts, retrofits, accessories,
    and older generation products. For current generation products,
    please see the GE BuyLog? or Control Catalog.
    Switchgear
    2-2 Aftermarket Catalog www.geelectrical.com Prices and data subject
    to change without notice
    Low Voltage Power and DC Circuit Breakers
    Low Voltage Switchgear History/Timeline
    GE Low Voltage Switchgear History/Timeline
    1930’s-50 AE/AL Manufactured from 1930’s(?) to the early 1950’s
    1951-75 AKD
    AK = Power Circuit Breaker Equipment
    D = Drawout circuit breaker construction
    Manufactured 1951 - 1975, all bolted copper bus design, all breakers drawout, AK-1, 2, 3 - 15 / 25 / 50 / 75 / 100.
    4000A max bus rating, 4 levels of bus, ring bus used in all feeder sections, main bus has provisions for future extension,
    sections in outdoor construction did not line up in the front, indoor construction has extended frames to allow
    the fronts of the sections to align. Indoor depths 49” (225 / 600A breakers), 59” (1600A breakers), 63” (3200 / 4000A
    breakers). Breakers had ratcheting drawout mechanism – open door drawout. Painted ANSI 61 light gray, manufactured
    in Philadelphia 1951 - mid-60’s, Bbington mid-60’s - 1975. Breaker compartment was a welded assembly,
    equipment frame was bolted. Breaker boxes were stacked to make a vertical section with equipment frame around
    the breaker boxes. No bus compartment barriers, open bus design. Ring silver plating on bolted connections.
    1951-60’s AKS Stationary version of AKD, manufactured 1951 - 60’s
    1960-77 AKD-5 Manufactured 1960 - 1977, aluminum bus with “flash-butt welded” copper to aluminum at bolted connections.
    AK-2A, 3A -25 / 50 / T50 / 75 / 100 (“A” signifies AKD-5 drawout). Pull-lanyard drawout mechanism on early
    design, replaced by single jackscrew mechanism and then replaced by double jack-screw mechanism. Closed-door
    drawout with inner house breaker compartment. 60” deep frame with 18” extension option. Outdoor protected
    aisle uses 60” deep indoor frame. Two bus levels available, ring bus used at 4000A. Welded / riveted frame, bus
    compartment barriers, line/load separation barriers on mains and ties, isolation barriers on transber transitions,
    copper runbacks on feeder breakers, ring silver plating on copper, aluminum bus unplated (welded connections).
    Painted sand gray (beige), some instrument doors painted blue. AKR-30/50 in 22” wide sections introduced
    in AKD-5 construction in early -70’s.
    1977-81 AKD-6 Manufactured in Salisbury, NC 1977 - 1981. Some AKD-5 construction built in Salisbury ’75 - ’77 and nameplated
    as AKD-6. No flash-butt welded aluminum to copper. Aluminum bus is tin plated and bolted at shipping splits (welded
    everywhere else). Copper bus design has ring silver plating at bolted joints. Introduced AKR-75 / 100. Stab-and-finger
    connections on 3200 and 4000A breakers versus round primary disconnect on AKD-5. Uses inner-house drawout breaker
    compartment. Tuning fork primary disconnect (extrusion) on 800 - 2000A breaker compartments. Copper feeder breaker
    runbacks. 60” deep frames with 18” optional rear extension. Painted ANSI 61 light gray. Breakers have ECS or SST trip units.
    1981- AKD-8 Manufactured 1981 to present. Model 1 & 2 has extruded vertical bus. Model 2 introduced in 1983 to accommodate
    present automated wiring programs and harness routing. Model 3 introduced in 1991 using flat bar vertical bus. Breakers use
    MicroVersa Trip 9, RMS9, EPIC, MVT Plus, MVT PM trip units. Aluminum bus removed from design in 1996 in favor of standard
    tin-plated copper bus (silver plating optional). Field convertible space compartment design added to allow empty
    compartments to be modified to functioning breaker compartment without modifications to vertical bus.
    1998- AKD-10 Introduced March 1998 as the successor to AKD-8. Manufactured along with AKD-8 for 1998 and 1999. Uses only
    present WavePro low voltage power circuit breakers. Same dimensions as AKD-8. Only changes from AKD-8 are in the front breaker
    compartment — new drawout rails, breaker door, secondary disconnects instrument panel. No need for Remote Display
    for trip unit since WavePro breaker has trip unit in the escutcheon. AKD-10 can match & line-up with AKD-8 without a transition
    (for indoor and outdoor construction). Same bus structure, frame, options, layouts and breaker stacking as AKD-8.
    2005- Enblisys Introduced October 2005 as a new platb for low voltage switchgear. Uses non-automatic EnbliGuard
    present breakers (similar to WavePro except no current sensors, no trip unit, and limited accessories). Enblisys uses redundant
    components for highest reliability and maximum up-time. Redundant CPU’s perb all protection, metering, control,
    and monitoring functions. Other redundant components of the system include 2 UPS’s, 2 network communication
    switches for internal communication, 2 control power throwover relays, 2 control power sources (120vAC). Each breaker
    cubicle is provided with an EnbliGuard Messenger, which is the interface between the CPU’s and the circuit breaker
    operating mechanisms. The Messenger perbs A/D and D/A conversions plus provides back-up overcurrent proteciton
    for the breaker if all control power and communications are lost.
    Equipment construction is the same as AKD-10 switchgear (frame, bussing, drawout cubicles, etc). Enblisys does
    not replace AKD-10. Both product lines are currently being produced.
    2
    Switchgear
    2
    Prices and data subject Aftermarket Catalog www.geelectrical.com 2-3
    to change without notice
    Low Voltage Power and DC Circuit Breakers
    Gerapid High Speed DC Circuit Breakers
    Technical Data for Rectifier Circuit Breaker Models 8007R and 10007R
    Breaker type Gerapid 8007R Gerapid 1007R
    Arc chute type 1x2 1x3 1x2 1x3
    Rated current In/A 6,000 6,000 8,000 8,000
    Rated operating voltage Ue/V 800 1,200 800 1,200
    Rated insulation voltage Ui/V 2,000 2,000 2,000 2,000
    120 min./A 7,200 7,200 9,600 9,600
    Short time current 2 min./A 8,000 8,000 16,000 16,000
    20 sec./A 12,000 12,000 24,000 24,000
    Mechanical endurance ops. 10,0001 10,0001 10,0001 10,0001
    Total weight approx. kg 220 220 220 220
    1With regular maintenance 100,000 ops.
    Figure 3. Gerapid 8007R and 10007R Rectifier CB, 1X2 Arc Chute, 800VDC
    (Dimensions in mm)
    Switchgear
    2
    2-4 Aftermarket Catalog www.geelectrical.com Prices and data subject
    to change without notice
    Low Voltage Power and DC Circuit Breakers
    AK and AKR Low Voltage Power Circuit Breakers
    New AK and AKR low voltage power circuit breakers are available for replacement and
    retrofill needs. The following circuit breakers are available:
    AK Circuit Breaker
    AC Voltage Rating Frame Size Short-circuit Ratings — RMS Symmetrical KA
    60 Hertz Breaker Type (Amps) With Instantaneous Trip Without Instantaneous Trip
    AK-25 600 22 22
    600 AK-50 1600 42 42
    AK-50H 1600 65 65
    AK-25 600 30 22
    480 AK-50 1600 50 50
    AK-50H 1600 65 65
    AK-25 600 42 22
    240 AK-50 1600 65 50
    AK-50H 1600 85 65
    AKR Circuit Breaker
    AC Voltage Rating Frame Size Short-circuit Ratings — RMS Symmetrical KA
    50/60 Hertz Breaker Type (Amps) With Instantaneous Trip Without Instantaneous Trip
    AKR-30 800 30 30
    AKR-30H 800 42 42
    600 AKR-50 1600 42 42
    AKR-50H 1600 65 65
    AKRT-50H 2000 65 65
    AKR-75 3200 65 65
    AKR-100 4000 85 85
    AKR-30 800 30 30
    AKR-30H 800 42 42
    480 AKR-50 1600 50 50
    AKR-50H 1600 65 65
    AKRT-50H 2000 65 65
    AKR-75 3200 65 65
    AKR-100 4000 85 85
    AKR-30 800 42 30
    AKR-30H 800 50 42
    240 AKR-50 1600 65 50
    AKR-50H 1600 65 65
    AKRT-50H 2000 65 65
    AKR-75 3200 85 65
    AKR-100 4000 130 85
    Contact your local GE sales representative for price and delivery. Be prepared to provide full
    nameplate data from your existing low voltage switchgear lineup.
    AK-25 Breaker
    AKR-30H Breaker
    Switchgear
    2
    Prices and data subject Aftermarket Catalog www.geelectrical.com 2-5
    to change without notice
    AK-25 Breaker with EnbliGuard? TU Trip Unit
    Low Voltage Power and DC Circuit Breakers
    Trip Unit Conversion Kits
    EnbliGuard? TU Conversion Kits
    GE offers a complete line of trip unit upgrade kits for low voltage
    power circuit breakers manufactured by GE, as well as by
    Westinghouse, I-T-E, and Allis-Chalmers. These conversion kits
    contain everything necessary to convert an old-style electromechanical
    or solid-state trip unit to today's latest electronic,
    digital technology—including the addition of metering, protective
    relay, waveb capture, RELT, and communication functions.
    All conversion kits designed by GE are tested to ANSI C37.59
    standards for each breaker type so customers have the
    assurance of safe, reliable operation.
    Features and Benefits–All Kits
    —Kit includes everything needed in one compact package
    —Full-range of interchangeable rating plugs
    —Trip targets for quick identification of overload, short circuit,
    and ground fault trips
    —Sealable, see-through cover to prevent unauthorized access to
    trip unit settings
    —Portable Trip Unit Test Kits; GTUTK20 and TVRMS2
    —Eliminate costly downtime due to nuisance tripping
    —Improved power system coordination and protection
    —Extend life and function of existing breakers and low voltage
    equipment
    EnbliGuard? TU Conversion Kits
    —True RMS sensing with a sampling rate of 48 samples per cycle
    with the ability to Waveb capture 4 cycles prior and 4 cycles
    after an event
    —Long Time, Short Time, and Instantaneous Standard on all trip
    units. S and I switchable on ANSI breakers
    —Large backlit LCD screen, view all currents on one screen
    —Trip settings and trip target inbation stored in non-volatile
    memory
    —On-board lithium battery (field replaceable) for cold set-up and
    reading trip targets
    —Status and Event Log, view the last 10 events
    —Health Status LED and Thermal Memory
    —Comm port for interface with set-up software and to download
    Waveb
    —Optional metering, relaying, communications, ZSI - I, ground
    fault (trip & alarm), and fused shaped curves
    —Plug and Play with previous generation of RMS9, EPIC, MVT and
    Enhanced MVT Trip Units
    ProTrip? Conversion Kits
    —Cost-effective upgrade with standard adjustable long time,
    short time, instantaneous, and defeatable ground fault functions
    —Simple-to-use rotary switches for selecting the trip unit pickup
    and delay settings
    —True RMS sensing with sampling rate of 48 times per cycle
    per phase - accurate waveb measurements through the
    11th harmonic
    —Standard target module with individual LEDs for overload pickup,
    overload trip, short circuit trip, ground fault trip, and target
    module battery monitor
    Everything You Need in One Package
    ProTrip? and EnbliGuard? TU conversion kits for the breakers
    listed in the following pages are shipped complete with detailed
    installation instructions and everything needed for fast and easy
    trip unit conversions.
    —Digital solid-state trip with quick disconnect
    —Direct-acting flux shift trip actuator with automatic reset
    —Epoxy encapsulated high-accuracy current sensors
    —Interchangeable rating plug (order separaby)
    —Specially designed mounting hardware and wire harnesses for
    each breaker frame
    Switchgear
    2
    2-6 Aftermarket Catalog www.geelectrical.com Prices and data subject
    to change without notice
    Low Voltage Power and DC Circuit Breakers
    Trip Unit Conversion Kits
    EnbliGuard? TU Trip Unit
    EnbliGuard? TU Conversion Kits—
    Upgrade your low-voltage equipment with
    electronic trip unit technology.
    Normal wear and tear of aging electro-mechanical trip devices
    on low-voltage circuit breakers increases susceptibility to loss of
    calibration that can subsequently jeopardize electrical power
    system coordination, protection and reliability.
    GE has channeled its decades of circuit breaker trip system
    experience into the development of the EnbliGuard? TU Trip Unit.
    The EnbliGuard? TU builds on the past trip units by incorporating
    advance algorithms that enable Arc Flash protection and
    Selectivity at the same time.
    ANSI C37.59 design verification tested to ensure safe, reliable
    operation, these kits are designed to extend the life of your
    mechanically sound breaker and…
    —Eliminate costly downtime due to nuisance tripping. Improves
    on past trip units with a Waveb Recognition Instantaneous
    Algorithm
    —Improve electrical power system coordination and protection
    —Permit easy upgrades to communicating Power Management
    Control Systems (PMCS), open Modbus RTU protocol
    —Enable the implementation of RELT and Zone Selective Interlock
    Instantaneous to reduce Arc Flash Energy Levels.
    Standard Features
    —Flexible Time Current Settings
    —I
    2T Long Time, Long Time Delay
    —Short Time, Short Time Delay, 3 Short Time I2T Slopes
    —Waveb Recognition Instantaneous
    —Ammeter
    —Large Backlit LCD Screen1
    —Date and Time1
    —Breaker Status Indication
    —Universal Rating Plugs
    —Status and Event Log (10 Events)
    —LED Health Status Indicator1
    —Set-up Software
    —I/O – 1 Input and 1 Output1
    —Thermal Memory, Battery Back-up
    —Common Interface across all versions
    Optional
    —Internal/External Ground Fault Trip or Alarm with 4 curves to
    select from (I2T, I4T, SGF, Definite Time Slope)1
    —Switchable Ground Fault Trip / Alarm (not UL Listed)
    —Fused Long Time Curves (I4T)
    —Modbus Open RTU Communications1
    —Waveb Capture – Enables Harmonic analysis
    —Full-function Metering1
    —Protective Relaying1
    —Zone Selective Interlock – GF, S, I1
    —RELT – Reduce Energy Let Through1
    —RELT and Ground Fault Alarm Harness Kits
    —Test Set GTUTK20
    Test Kit – GTUTK20
    Arc Flash and Selectivity at the same time
    The EnbliGuard? TU Trip Unit offers optimum circuit protection
    and optimum system reliability simultaneously with little or no
    compromise to either of these critical functions. Reliability and arc
    flash protection, in one package, at the same time, all the time.
    Algorithms enabling arc flash protection and selectivity
    —RELT – Reduced Energy Let Through
    —Zone Selective Interlocking – Instantaneous (ZSI-I)
    —Waveb Recognition Instantaneous – Coordinate with Current
    Limiting Devices and reduces Nuisance Trips
    —Flexible Time Current Curves – Create the shape you need
    Reliability – Health Status
    —Non-volatile memory with continuous self-testing microprocessor
    —Health Status LED indicates Normal Operation, Errors, Pick-up, Trip
    —External Power Not Required with Long Life Lithium Battery
    —Positive setpoint recognition, values flash until saved
    Plug and Play
    —Same Form, Fit, Function as the popular MicroVersaTrip? Trip
    Unit. Easily upgrade an existing converted breaker1
    Optional Full-function metering including
    —current (Amps, kAmps)
    —voltage (Ph-Ph, Ph-N)
    —energy (kWh, MWh, GWh)
    —real power (kW, MW)
    —total power (kVA, MVA)
    —frequency (Hz)
    —demand (avg. kW, MW) and peak demand
    Optional protective relaying functions include
    —undervoltage
    —overvoltage
    —voltage unbalance
    —current unbalance
    —power reversal
    —power direction setup
    1Note: Some options require 24VDC, additional hardware to enable Metering,
    Relaying, RELT, ZSI, Modbus to be added to the Breaker, Equipment Cubicle,
    and Equipment Sections.
    Switchgear
    2
    Prices and data subject Aftermarket Catalog www.geelectrical.com 2-7
    to change without notice
    Low Voltage Power and DC Circuit Breakers
    ProTrip? Trip Unit Conversion Kit Selection Guide
    For GE Circuit Breakers
    Product Number Structure
    PK115 3 F 01 08 D
    Breaker
    AK-1-15
    AK-15
    AK-1-25
    AK-25
     AKU-25
    AK-1-50
     AK-50
    AKU-502
     AKT-50
    AKS-50
    AKSU-502
     AKST-50
    AK-753
     AK-1003
    Wiring
     3 Wire-3
     4 Wire-4
    Sensor Type
     Fixed CTs-F
    For converting AK-2 version breakers and newer, not applicable for AK-1 or AKR
    Breakers equipped with older style open fuse lockout devices (OFLO), must be
    retrofitted with newer style OFLO device prior to conversion process.
    Order replacement OFLO kits as follows: AKU-50 - order OFLO kit #121C287OG2,
    AK-75 - order OFLO kit #121C287OG3, AK-100 - order OFLO kit #121C287OG4
    Contact the factory for stationary breaker applications
    Trip Functions
    LSIGX- 08
    Trip Unit Functions
    LSIGX- Long Time, Short Time/INST.
     and Switchable Ground Fault (off)
     Not Approved for a UL Listed Breaker
    Model
    Generation-D
    Sensor Rating
    150A- 01
     225A- 02
     600A- 06
     800A- 08
     1600A- 16
     2000A- 20
     3000A- 30
     4000A- 40
    Sensor Rating Selection
     Frame Breaker Product Numbers Sensors
    PK115
    PKO151
    PK125
    PKO753
    PKO501
    PK150
    PKO251
    PKO103
    225 AK-1-15, AK-15 150A, 225A
    600 AK-1-25, AK-25, AKU-25 150A, 225A, 600A
     AK-1-50, AK-50, AKU-50,
     AKS-50, AKSU-50
    2000 AKT-50, AKST-50 2000A
    3000 AK-75 3000A
    4000 AK-100 4000A
    1600 800A, 1600A
    1
    2
    3
    ProTrip? Conversion Kits
    List Price
    Frame Size (Amps) Breaker Model Wiring Sensor Rating Product Number GO-104P
    225 AK-1-15 3 Wire 150A PK115D3F0108 緯軒機電2550.00
    225 AK-1-15 3 Wire 225A PK115D3F0208 緯軒機電2550.00
    225 AK-1-15 4 Wire 150A PK115D4F0108 緯軒機電2775.00
    225 AK-1-15 4 Wire 225A PK115D4F0208 緯軒機電2775.00
    225 AK-15 3 Wire 150A PKO15D3F0108 緯軒機電2550.00
    225 AK-15 3 Wire 225A PKO15D3F0208 緯軒機電2550.00
    225 AK-15 4 Wire 150A PKO15D4F0108 緯軒機電2775.00
    225 AK-15 4 Wire 225A PKO15D4F0208 緯軒機電2775.00
    600 AK-1-25 3 Wire 150A PK125D3F0108 緯軒機電2550.00
    600 AK-1-25 3 Wire 225A PK125D3F0208 緯軒機電2550.00
    600 AK-1-25 3 Wire 600A PK125D3F0608 緯軒機電2550.00
    600 AK-1-25 4 Wire 150A PK125D4F0108 緯軒機電2775.00
    600 AK-1-25 4 Wire 225A PK125D4F0208 緯軒機電2775.00
    600 AK-1-25 4 Wire 600A PK125D4F0608 緯軒機電2775.00
    600 AK-25, AKU-25 3 Wire 150A PKO25D3F0108 緯軒機電2550.00
    600 AK-25, AKU-25 3 Wire 225A PKO25D3F0208 緯軒機電2550.00
    600 AK-25, AKU-25 3 Wire 600A PKO25D3F0608 緯軒機電2550.00
    600 AK-25, AKU-25 4 Wire 150A PKO25D4F0108 緯軒機電2775.00
    600 AK-25, AKU-25 4 Wire 225A PKO25D4F0208 緯軒機電2775.00
    600 AK-25, AKU-25 4 Wire 600A PKO25D4F0608 緯軒機電2775.00
    1600 AK-1-50 3 Wire 800A PK150D3F0808 緯軒機電2800.00
    1600 AK-1-50 3 Wire 1600A PK150D3F1608 緯軒機電2800.00
    1600 AK-1-50 4 Wire 800A PK150D4F0808 緯軒機電3025.00
    1600 AK-1-50 4 Wire 1600A PK150D4F1608 緯軒機電3025.00
    1600 AK-50, AKU-50, AKT-50, AKS-50, AKSU-50, AKST-50 3 Wire 800A PKO50D3F0808 緯軒機電2800.00
    1600 AK-50, AKU-50, AKT-50, AKS-50, AKSU-50, AKST-50 3 Wire 1600A PKO50D3F1608 緯軒機電2800.00
    1600 AK-50, AKU-50, AKT-50, AKS-50, AKSU-50, AKST-50 3 Wire 2000A PKO50D3F2008 緯軒機電2800.00
    1600 AK-50, AKU-50, AKT-50, AKS-50, AKSU-50, AKST-50 4 Wire 800A PKO50D4F0808 緯軒機電3025.00
    1600 AK-50, AKU-50, AKT-50, AKS-50, AKSU-50, AKST-50 4 Wire 1600A PKO50D4F1608 緯軒機電3025.00
    1600 AK-50, AKU-50, AKT-50, AKS-50, AKSU-50, AKST-50 4 Wire 2000A PKO50D4F2008 緯軒機電3025.00
    3000 AK-75 3 Wire 3000A PKO75D3F3008 緯軒機電2800.00
    3000 AK-75 4 Wire 3000A PKO75D4F3008 緯軒機電3025.00
    4000 AK-100 3 Wire 4000A PKO10D3F4008 緯軒機電3050.00
    4000 AK-100 4 Wire 4000A PKO10D4F4008 緯軒機電3275.00
    Conversion kits come standard with a rating plug that matches the current sensor. For rating plugs with different values, price and order separaby. See page 2-11.
    Switchgear
    2
    2-8 Aftermarket Catalog www.geelectrical.com Prices and data subject
    to change without notice
    Low Voltage Power and DC Circuit Breakers
    ProTrip? Trip Unit Conversion Kit Selection Guide
    For *I-T-E Circuit Breakers
    Product Number Structure
    PIK22 D 3 F 02 08
    Breaker
    K225
    K600
    KD0N600
    K800
     KD0N800
     K1600 (black)
     KD0N1600 (black)
     K1600 (red)
     KD0N1600 (red)
    Wiring
     3 Wire-3
     4 Wire-4
    Sensor Type
     Fixed CTs-F
    Applicable to breakers originally equipped with either electro-mechanical
    trip devices or with solid state trip devices ("S" version breakers).
    Only applicable to breakers originally equipped with rectangular shaped
    primary disconnect assemblies.
    Only applicable to breakers originally equipped with circular shaped
    primary disconnect assemblies.
    Trip Functions
    LSIGX- 08
    Trip Unit Functions
    LSIGX- Long Time, Short Time/INST.
     and Switchable Ground Fault (off)
     Not Approved for a UL Listed Breaker
    Model
    Generation-D
    Sensor Rating
    150A- 01
     225A- 02
     400A- 04
     600A- 06
     800A- 08
     1600A- 16
    Sensor Rating Selection
     Frame Breaker Product Numbers Sensors
    PIK221
    PIK601
    PIK801
    PIK1B1
    PIK161,2
    PIKN1,3
    225 K225 150A, 225A
    600 K600, KD0N600 150A, 225A, 600A
    800 K800, KD0N800 150A, 400A, 800A
     K1600 (black),
    1600 KD0N1600 (black), 800A, 1600A
     K1600 (red), KD0N1600 (red)
    1
    2
    3
    ProTrip? Conversion Kits
    List Price
    Frame Size (Amps) Breaker Model Wiring Sensor Rating Product Number GO-104P
    225 K225 3 Wire 150A PIK22D3F0108 緯軒機電2450.00
    225 K225 3 Wire 225A PIK22D3F0208 緯軒機電2450.00
    225 K225 4 Wire 150A PIK22D4F0108 緯軒機電2675.00
    225 K225 4 Wire 225A PIK22D4F0208 緯軒機電2675.00
    600 K600, KDON600 3 Wire 150A PIK60D3F0108 緯軒機電2350.00
    600 K600, KDON600 3 Wire 225A PIK60D3F0208 緯軒機電2350.00
    600 K600, KDON600 3 Wire 600A PIK60D3F0608 緯軒機電2350.00
    600 K600, KDON600 4 Wire 150A PIK60D4F0108 緯軒機電2575.00
    600 K600, KDON600 4 Wire 225A PIK60D4F0208 緯軒機電2575.00
    600 K600, KDON600 4 Wire 600A PIK60D4F0608 緯軒機電2575.00
    800 K800, KDON800 3 Wire 150A PIK80D3F0108 緯軒機電2350.00
    800 K800, KDON800 3 Wire 400A PIK80D3F0408 緯軒機電2350.00
    800 K800, KDON800 3 Wire 800A PIK80D3F0808 緯軒機電2350.00
    800 K800, KDON800 4 Wire 150A PIK80D4F0108 緯軒機電2575.00
    800 K800, KDON800 4 Wire 400A PIK80D4F0408 緯軒機電2575.00
    800 K800, KDON800 4 Wire 800A PIK80D4F0808 緯軒機電2575.00
    1600 K1600 (black), KDON1600 (black) 3 Wire 800A PIK1BD3F0808 緯軒機電2700.00
    1600 K1600 (black), KDON1600 (black) 3 Wire 1600A PIK1BD3F1608 緯軒機電2700.00
    1600 K1600 (black), KDON1600 (black) 4 Wire 800A PIK1BD4F0808 緯軒機電2925.00
    1600 K1600 (black), KDON1600 (black) 4 Wire 1600A PIK1BD4F1608 緯軒機電2925.00
    1600 K1600 (red) 3 Wire 800A PIK16D3F0808 緯軒機電2700.00
    1600 K1600 (red) 3 Wire 1600A PIK16D3F1608 緯軒機電2700.00
    1600 K1600 (red) 4 Wire 800A PIK16D4F0808 緯軒機電2925.00
    1600 K1600 (red) 4 Wire 1600A PIK16D4F1608 緯軒機電2925.00
    1600 KDON1600 (red) 3 Wire 800A PIKN1D3F0808 緯軒機電2700.00
    1600 KDON1600 (red) 3 Wire 1600A PIKN1D3F1608 緯軒機電2700.00
    1600 KDON1600 (red) 4 Wire 800A PIKN1D4F0808 緯軒機電2925.00
    1600 KDON1600 (red) 4 Wire 1600A PIKN1D4F1608 緯軒機電2925.00
    Conversion kits come standard with a rating plug that matches the current sensor. For rating plugs with different values, price and order separaby. See page 2-11.
    *I-T-E is a registered trademark of Siemens Energy and Automation, Inc.
    Switchgear
    2
    Prices and data subject Aftermarket Catalog www.geelectrical.com 2-9
    to change without notice
    Low Voltage Power and DC Circuit Breakers
    ProTrip? Trip Unit Conversion Kit Selection Guide
    For *Allis-Chalmers Circuit Breakers
    Product Number Structure
    PSL6B 3 F 02 08 D
    Breaker
    LA-600 (blue)
    LAF-600 (blue)
    LA-600 (gold)
    LAF-600 (gold)
    LA-800 (gold)
    LAF-800 (gold)
     LA-1600 (blue)
    LAF-1600 (blue)
     LA-1600 (gold)
    LAF-1600 (gold)
    Wiring
     3 Wire-3
     4 Wire-4
    Sensor Type
     Fixed CTs-F
    Trip Functions
    LSIGX- 08
    Trip Unit Functions
    LSIGX- Long Time, Short Time/INST.
     and Switchable Ground Fault (off)
     Not Approved for a UL Listed Breaker
    Model
    Generation-D
    Sensor Rating
    150A- 01
     225A- 02
     400A- 04
     600A- 06
     800A- 08
     1600A- 16
    Sensor Rating Selection
     Frame Breaker Product Numbers Sensors
     LA-600 (blue), LAF-600 (blue)
     LA-600 (gold), LAF-600 (gold)
     LA-800 (gold), LAF-800 (gold)
     LA-1600 (blue), LAF-1600 (blue)
     LA-1600 (gold), LAF-1600 (gold)
    PSL6B
    PSL6G
    PSL8O
    PSL1B
    PSL1G
    600
    800
    1600
    150A, 225A, 600A
    150A, 400A, 800A
    800A, 1600A
    ProTrip? Conversion Kits
    List Price
    Frame Size (Amps) Breaker Model Wiring Sensor Rating Product Number GO-104P
    600 LA-600 (blue), LAF-600 (blue) 3 Wire 150A PSL6BD3F0108 緯軒機電2350.00
    600 LA-600 (blue), LAF-600 (blue) 3 Wire 225A PSL6BD3F0208 緯軒機電2350.00
    600 LA-600 (blue), LAF-600 (blue) 3 Wire 600A PSL6BD3F0608 緯軒機電2350.00
    600 LA-600 (blue), LAF-600 (blue) 4 Wire 150A PSL6BD4F0108 緯軒機電2575.00
    600 LA-600 (blue), LAF-600 (blue) 4 Wire 225A PSL6BD4F0208 緯軒機電2575.00
    600 LA-600 (blue), LAF-600 (blue) 4 Wire 600A PSL6BD4F0608 緯軒機電2575.00
    600 LA-600 (gold), LAF-600 (gold) 3 Wire 150A PSL6GD3F0108 緯軒機電2350.00
    600 LA-600 (gold), LAF-600 (gold) 3 Wire 225A PSL6GD3F0208 緯軒機電2350.00
    600 LA-600 (gold), LAF-600 (gold) 3 Wire 600A PSL6GD3F0608 緯軒機電2350.00
    600 LA-600 (gold), LAF-600 (gold) 4 Wire 150A PSL6GD4F0108 緯軒機電2575.00
    600 LA-600 (gold), LAF-600 (gold) 4 Wire 225A PSL6GD4F0208 緯軒機電2575.00
    600 LA-600 (gold), LAF-600 (gold) 4 Wire 600A PSL6GD4F0608 緯軒機電2575.00
    800 LA-800 (gold) 3 Wire 150A PSL80D3F0108 緯軒機電2500.00
    800 LA-800 (gold) 3 Wire 400A PSL80D3F0408 緯軒機電2500.00
    800 LA-800 (gold) 3 Wire 800A PSL80D3F0808 緯軒機電2500.00
    800 LA-800 (gold) 4 Wire 150A PSL80D4F0108 緯軒機電2725.00
    800 LA-800 (gold) 4 Wire 400A PSL80D4F0408 緯軒機電2725.00
    800 LA-800 (gold) 4 Wire 800A PSL80D4F0808 緯軒機電2725.00
    1600 LA-1600 (blue), LAF-1600 (blue) 3 Wire 800A PSL1BD3F0808 緯軒機電2700.00
    1600 LA-1600 (blue), LAF-1600 (blue) 3 Wire 1600A PSL1BD3F1608 緯軒機電2700.00
    1600 LA-1600 (blue), LAF-1600 (blue) 4 Wire 800A PSL1BD4F0808 緯軒機電2925.00
    1600 LA-1600 (blue), LAF-1600 (blue) 4 Wire 1600A PSL1BD4F1608 緯軒機電2925.00
    1600 LA-1600 (gold), LAF-1600 (gold) 3 Wire 800A PSL1GD3F0808 緯軒機電2700.00
    1600 LA-1600 (gold), LAF-1600 (gold) 3 Wire 1600A PSL1GD3F1608 緯軒機電2700.00
    1600 LA-1600 (gold), LAF-1600 (gold) 4 Wire 800A PSL1GD4F0808 緯軒機電2925.00
    1600 LA-1600 (gold), LAF-1600 (gold) 4 Wire 1600A PSL1GD4F1608 緯軒機電2925.00
    Conversion kits come standard with a rating plug that matches the current sensor. For rating plugs with different values, price and order separaby. See page 2-11.
    *Allis-Chalmers is a trademark of Allis-Chalmers Manufacturing Company Corporation.
    Switchgear
    2
    2-10 Aftermarket Catalog www.geelectrical.com Prices and data subject
    to change without notice
    Low Voltage Power and DC Circuit Breakers
    ProTrip? Trip Unit Conversion Kit Selection Guide
    For *Westinghouse Circuit Breakers
    Product Number Structure
    PDB15 3 F 02 08 D
    Breaker
    DB15, DBL15- PDB15
    DB25, DBL25- PDB25
    DB50, DBL50- PDB50
    DB75- PDB75
    DB100- PDB10
    Wiring
     3 Wire-3
     4 Wire-4
    Sensor Type
     Fixed CTs-F
    Trip Functions
    LSIGX- 08
    Trip Unit Functions
    LSIGX- Long Time, Short Time/INST.
     and Switchable Ground Fault (off)
     Not Approved for a UL Listed Breaker
    Model
    Generation-D
    Sensor Rating
    150A- 01
     225A- 02
     600A- 06
     800A- 08
     1600A- 16
     3000A- 30
     4000A- 40
    Sensor Rating Selection
     Frame Breaker Product Numbers Sensors
     225 DB15, DBL15 150A, 225A
     600 DB25, DBL25 225A, 600A
     1600 DB50, DBL50 800A,1600A
     3000 DB75 3000A
     4000 DB100 4000A
    ProTrip? Conversion Kits
    List Price
    Frame Size (Amps) Breaker Model Wiring Sensor Rating Product Number GO-104P
    225 DB15, DBL15 3 Wire 150A PDB15D3F0108 緯軒機電2250.00
    225 DB15, DBL15 3 Wire 225A PDB15D3F0208 緯軒機電2250.00
    225 DB15, DBL15 4 Wire 150A PDB15D4F0108 緯軒機電2475.00
    225 DB15, DBL15 4 Wire 225A PDB15D4F0208 緯軒機電2475.00
    600 DB25, DBL25 3 Wire 150A PDB25D3F0108 緯軒機電2350.00
    600 DB25, DBL25 3 Wire 225A PDB25D3F0208 緯軒機電2350.00
    600 DB25, DBL25 3 Wire 600A PDB25D3F0608 緯軒機電2350.00
    600 DB25, DBL25 4 Wire 150A PDB25D4F0108 緯軒機電2575.00
    600 DB25, DBL25 4 Wire 225A PDB25D4F0208 緯軒機電2575.00
    600 DB25, DBL25 4 Wire 600A PDB25D4F0608 緯軒機電2575.00
    1600 DB50, DBL50 3 Wire 800A PDB50D3F0808 緯軒機電2350.00
    1600 DB50, DBL50 3 Wire 1600A PDB50D3F1608 緯軒機電2350.00
    1600 DB50, DBL50 4 Wire 800A PDB50D4F0808 緯軒機電2575.00
    1600 DB50, DBL50 4 Wire 1600A PDB50D4F1608 緯軒機電2575.00
    3000 DB75 3 Wire 3000A PDB75D3F3008 緯軒機電2600.00
    3000 DB75 4 Wire 3000A PDB75D4F3008 緯軒機電2825.00
    4000 DB100 3 Wire 4000A PDB10D3F4008 緯軒機電2850.00
    4000 DB100 4 Wire 4000A PDB10D4F4008 緯軒機電3075.00
    Conversion kits come standard with a rating plug that matches the current sensor. For rating plugs with different values, price and order separaby. See page 2-11.
    *Westinghouse is a trademark of Westinghouse Electric Corporation.
    Switchgear
    2
    Prices and data subject Aftermarket Catalog www.geelectrical.com 2-11
    to change without notice
    *I-T-E is a registered trademark of Siemens Energy and Automation, Inc.
    *Westinghouse is a trademark of Westinghouse Electric Corporation.
    *Allis-Chalmers is a trademark of Allis-Chalmers Manufacturing Company Corporation.
    Low Voltage Power and DC Circuit Breakers
    ProTrip? Rating Plugs
    ProTrip? conversion kits come standard with a rating plug that
    matches the current sensor. For rating plugs with different values,
    price and order separaby.
    Rating Plug
    Reference Publications
    ProTrip? Trip Unit Conversion Kits for
    GE Power Circuit Breakers - Fact Sheet DET-228
    ProTrip? Trip Unit Conversion Kits for
    *Westinghouse Power Circuit Breakers - Fact Sheet DET-230
    ProTrip? Trip Unit Conversion Kits for
    *Allis-Chalmers Power Circuit Breakers - Fact Sheet DET-231
    ProTrip? Trip Unit Conversion Kits for
    *I-T-E Power Circuit Breakers - Fact Sheet DET-229
    Rating Plugs
    List Price
    Frame Size (Amps) Sensor Rating (Amps) Current Rating (Amps) Current Range (Amps) Product Number GO-104P
    225|600|800 150 80 40-88 PT1C80GFD 緯軒機電149.00
    225|600|800 150 100 50-110 PT1C100GFD 緯軒機電149.00
    225|600|800 150 125 63-138 PT1C125GFD 緯軒機電149.00
    225|600|800 150 150 75-165 PT1C150GFD1 緯軒機電149.00
    225|600|800 225 150 75-165 PT225C150GFD 緯軒機電149.00
    225|600|800 225 225 113-248 PT225C225GFD1 緯軒機電149.00
    600 600 300 150-330 PT6C300GFD 緯軒機電149.00
    600 600 400 200-440 PT6C400GFD 緯軒機電149.00
    600 600 450 225-495 PT6C450GFD 緯軒機電149.00
    600 600 500 250-550 PT6C500GFD 緯軒機電149.00
    600 600 600 300-660 PT6C600GFD1 緯軒機電149.00
    800 400 200 100-220 PT4C200GFD 緯軒機電149.00
    800 400 225 113-248 PT4C225GFD 緯軒機電149.00
    800 400 250 125-275 PT4C250GFD 緯軒機電149.00
    800 400 300 150-330 PT4C300GFD 緯軒機電149.00
    800 400 400 200-440 PT4C400GFD1 緯軒機電149.00
    800|1600 800 400 200-440 PT8C400GFD 緯軒機電149.00
    800|1600 800 450 225-495 PT8C450GFD 緯軒機電149.00
    800|1600 800 500 250-550 PT8C500GFD 緯軒機電149.00
    800|1600 800 600 300-660 PT8C600GFD 緯軒機電149.00
    800|1600 800 700 350-770 PT8C700GFD 緯軒機電149.00
    800|1600 800 800 400-880 PT8C800GFD1 緯軒機電149.00
    1600 1600 800 400-880 PT16C800GFD 緯軒機電149.00
    1600 1600 1000 500-1100 PT16C1000GFD 緯軒機電149.00
    1600 1600 1100 550-1210 PT16C1100GFD 緯軒機電149.00
    1600 1600 1200 600-1320 PT16C1200GFD 緯軒機電149.00
    1600 1600 1600 800-1760 PT16C1600GFD 緯軒機電149.00
    2000 2000 1000 500-1100 PT20C1000GFD 緯軒機電149.00
    2000 2000 1200 600-1320 PT20C1200GFD 緯軒機電149.00
    2000 2000 1500 750-1650 PT20C1500GFD 緯軒機電149.00
    2000 2000 1600 800-1760 PT20C1600GFD 緯軒機電149.00
    2000 2000 2000 1000-2200 PT20C2000GFD 緯軒機電149.00
    3000 3000 1200 600-1320 PT30C1200GFD 緯軒機電149.00
    3000 3000 1600 800-1760 PT30C1600GFD 緯軒機電149.00
    3000 3000 2000 1000-2200 PT30C2000GFD 緯軒機電149.00
    3000 3000 2500 1250-2750 PT30C2500GFD 緯軒機電149.00
    3000 3000 3000 1500-3300 PT30C3000GFD1 緯軒機電149.00
    4000 4000 1600 800-1760 PT40C1600GFD 緯軒機電149.00
    4000 4000 2000 1000-2200 PT40C2000GFD 緯軒機電149.00
    4000 4000 2500 1250-2750 PT40C2500GFD 緯軒機電149.00
    4000 4000 3000 1500-3300 PT40C3000GFD 緯軒機電149.00
    4000 4000 3600 1800-3960 PT40C3600GFD 緯軒機電149.00
    4000 4000 4000 2000-4000 PT40C4000GFD1 緯軒機電149.00
    Rating Plug furnished with conversion kit.
    Note: Long Time pickup range is 0.5-1.1 times the rating plug value. 1.1 setting allows the breaker to carry 100% of the rating plug current value, not to exceed the
    continuous current (frame) rating of the breaker.
    Switchgear
    2
    2-12 Aftermarket Catalog www.geelectrical.com Prices and data subject
    to change without notice
    Low Voltage Power and DC Circuit Breakers
    EnbliGuard? TU Trip Unit
    Conversion Kits Selection Guide
    Sensor Rating Selection
    AKO25 C 3 F 06 04 A
    Breaker
    AK-1-15 = AK115
    AK-15 = AKO151
    AK-1-25 = AK125
    AK-25
    AKU-25 = AKO251
    AKR-30
    AKR-30H = AKR30
    AKRU-30
    AKR-30S
    AKRU-30S = AKR3S2
    AK-1-50 = AK150
    AK-50
    AKU-503
    AKT-50 = AKO501
    AKS-50
    AKSU-503
    AKST-50
    AKR-50
    AKR-50H
    AKRU-50
    AKRT-50
    AKRT-50H = AKR504
    AKJ-50
    AKJ-50H
    AKJT-50
    AKJT-50H
    AK-753 = AKO755
    AKR-75 = AKR755
    AK-1003 = AKO105
    AKR-100 = AKR105
    AKW-100 = AKW105
    Breaker
    DB-15 = ADB15
    DK-15 = ADK159
    DB-25
    DBL-25 = ADB25
    DK-25 = ADK259
    DS-206
    DSL-206 = ADS06
    DA-50 = ADA509
    DB-50
    DBL-50 = ADB50
    DS-416 = ADS16 DSL-416
    DS-420 = ADS20
    DS-532 = ADS539
    DA-75 = ADA759
    DB-75 = ADB75
    DS-632 = ADS32
    DA-100 = ADA109
    DB-100 = ADB10
    DS-840 = ADS409
    GE ***Westinghouse25 *Allis-Chalmers25 **I-T-E25
    Breaker
    LA = ASL259
    LA-25A = ASL2A9
    LA-600(Blue) = ASL6B17,18
    LAF-600(Blue) = ASL6B17,18,19
    LA-600(Gold) = ASL6G18,20
    LAF-600(Gold) = ASL6G18,19,20
    LA-50(800A) = ASL589,21
    LA-800 = ASL8018,20
    LAF-800 = ASL8018,19,20
    RL-800 = ASR80
    RLX-800 = ASR80
    RLE-800 = ASR80
    LA-50(1600A) = ASL519,22
    LA-50(1600A) = ASL529,23
    LA-1600(Blue) = ASL1B17,18
    LAF-1600(Blue) = ASL1B17,18,19
    LA-1600(Gold) = ASL1G18,20
    LAF-1600(Gold) = ASL1G18,19,20
    RL-1600 = ASR16
    RLX-1600 = ASR16
    RLE-1600 = ASR16
    RL-2000 = ASR09
    LA-75 = ASL759
    LA-3000 = ASL309,18
    LA-3200(Blue) = ASL3B9,
    17,18
    LA-3200(Gold) = ASL3G9,18,20
    RL-3200 = ASR329
    LA-4000(Blue) = ASL4B9,17,18
    LA-4000(Gold) = ASL4G9,18,20
    RL-4000 = ASR409
    Breaker
    KA = AIKA210,11
    K-225 = AIK22
    KB (bl) = AIKBM12
    KB (slate drawout) = AIKBS12
    KB (slate stationary) = AIKBX12
    K-600
    KDON-600 = AIK60
    KC (800A) = AIKC810,12,14
    K-800 = AIK80 KDON-800
    KC (1600A) = AIKC110,12,13
    K-1600 (red) = AIK1615
    K-1600 (black) = AIK1B15
    KDON-1600 (black)
    KDON-1600 (red) = AIKN1
    K-2000 = AIK20
    KD = AIKD316
    K-3000 = AIK30
    KE = AIKE416
    LG = AIKG49
    K-4000 = AIK40
    Blue = Blue-gray breaker with plastic escutcheon
    Gold = Gold breaker with bl escutcheon
    Frame Sensors
    Breaker Catalog Numbers
    GE *Allis-Chalmers **I-T-E ***Westinghouse
    225 150 AK-1-15, AK-15 Sensor rating not available. KA, KA-225 DB-15, DK-15 225
    600
    150
    AK-1-25, AK-25, AKU-25
    — — —
    225 LA-25, LA-25A, LA-600,
    LAF-600 KB, K-600, KDON-600 DB-25, DBL-25, DK-25 600
    800
    150 AKR-30, AKR-30H, AKRU-30,
    AKR-30S, AKRU-30S
    LA-50 (800A Version), LA-800, LAF-800,
    RL-800, RLE-800, RLX-800
    KC (800A Version),
    K-800, KDON-800 400 DS-206, DSL-206
    800
    1600
    800 AK-1-50, AK-50, AKU-50, AKS-50,
    AKSU-50, AKR-50, AKR-50H,
    AKRU-50, AKJ-50, AKJ-50H
    LA-50 (1600A Version),
    LA-1600, LAF-1600, RL-1600,
    RLE-1600, RLX-1600
    KC (1600A Version),
    K-1600, KDON-1600
    DA-50, DB-50, DBL-50,
    DS-416, DSL-416 1600
    2000 2000 AKT-50, AKST-50, AKRT-50,
    AKRT-50H, AKJT-50, AKJT-50H RL-2000 K-2000 DS-420
    3000 3000 AK-75 LA-75, LA-3000 KD, K-3000 DA-75, DB-75
    3200 3200 AKR-75 LA-3200, RL-3200 — DS-632
    4000 4000 AK-100, AKR-100, AKW-100 LA-4000, RL-4000 KE, LG, K-4000 DA-100, DB-100, DS-840
    *Allis-Chalmers is a trademark of Allis-Chalmers Manufacturing Company Corporation.
    **I-T-E is a registered trademark of Siemens Energy and Automation, Inc.
    ***Westinghouse is a trademark of Westinghouse Electric Corporation.
    Switchgear
    2
    Prices and data subject Aftermarket Catalog www.geelectrical.com 2-13
    to change without notice
    Low Voltage Power and DC Circuit Breakers
    EnbliGuard? TU Trip Unit
    Conversion Kits Selection Guide
    1For converting AK-2 version breakers and newer, not applicable for AK-1 or AKR.
    2AKR30S Instantaneous Is Non-Switchable and the Non-Switchable High Range
    Instantaneous max is 22KA. LSH and LSHG Are Only Available on AKR30S.
    3Breakers equipped with older style open fuse lockout devices (OFLO), must be
    retrofitted with newer style OFLO device prior to conversion process. Order
    replacement OFLO kits as follows: AKU-50 - order OFLO Kit #121C2870G2,
    AK-75 - order OFLO kit #121C2870G3, AK-100 - order OFLO kit #121C2870G4.
    4Not applicable for converting breakers equipped with Power Sensor - contact
    factory.
    5Contact the factory for stationary breaker applications.
    6Only applicable to trip units with ground fault.
    7Available only for MicroVersaTrip RMS-9 type AKR breakers equipped with fixed
    current sensors.
    8Not available on AK-75 breaker frames.
    9Contact factory for availability.
    10Not applicable for slate version breakers.
    11Left pole accessories must be removed or relocated.
    12Right pole accessories must be removed or relocated.
    131600-amp version of the KC breaker.
    14800-amp version of the KC breaker.
    15Order for red or black insulator as applicable.
    16Not applicable to fixed mounted breakers.
    17Only applicable for blue-gray color version breakers.
    18Applicable to both “A” and “B” version breakers.
    19Applicable to both nameplated versions of integral fused breakers
    (i.e., LA-600F and LAF-600).
    20Only applicable for gold color version breakers.
    21800-amp version of the LA-50 breaker.
    22Only applicable for the 1600-amp, 6-pole primary disconnect version of
    the LA-50 breaker.
    23Only applicable for 1600-amp, 12 pole primary disconnect version of the
    LA-50 breaker.
    24Requires 24VDC control power.
    25Existing Allis-Chalmers, I-T-E and Westinghouse bell alarms will not work
    with EnbliGuard TU..
    Model
    C = Generation
    Wiring
    3 Wire = 3
    4 Wire6 = 4
    Sensor Type
    F = Fixed CTs
    Sensor Ratings
    150A = 01
    225A = 02
    400A = 04
    600A = 06
    800A = 08
    1600A = 16
    2000A = 20
    3000A = 30
    3200A8 = 32
    4000A = 40
    150A No CTs7 = XA
    400A No CTs7 = XC
    800A No CTs7 = XE
    1600A No CTs7 = XF
    2000A No CTs7 = XG
    3200A No CTs7,8 = XI
    4000A No CTs7 = XJ
    Trip Functions
    04 = LSI2
    05 = LSIG2
    09 = LSIGDA
    11 = LSH2
    12 = LSHG2
    Adv. Options
    A = Ammeter
    B = Ammeter + RELT24
    C = Advanced Metering, Relaying,
    Waveb Capture, Modbus Comm,
    RELT24
    Trip Unit Functions
    LSI = Long Time, Short Time (Switchable),
    & Instantaneous (Switchable)
    LSIG = LSI & Ground Fault Trip
    LSIGDA = LSIG with Switchable Ground
    Fault Alarm (not UL Listed)
    LSH = Long Time, Short Time (Switchable),
    High Range Instantaneous
    (Non-Switchable) Up to 22KA
    (AKR30S Only)2
    LSHG = LSH & Ground Fault Trip
    (AKR30S Only)2
    ZSI – Instantaneous is available.
    Contact factory.
    RELT (Reduced Energy Let Through) –
    Order RELT Switch Kit GTURSK separaby
    Kits Without Sensors
    For kits ordered without sensors, deduct 緯軒機電200.00 from the list price of
    the kit with sensors. Please refer to the sensor rating column above for
    the appropriate “X” sensor code.
    Zone Selective Interlock
    For Zone Selective Interlock (ZSI) Short Time, Ground Fault and
    Instantaneous, add 緯軒機電550.00 to the list price. (Also requires purchase of
    ZSI module TIM1 [120 VAC control voltage], list price 緯軒機電402.00, GO-245B.)
    Reference Publications
    EnbliGuard? TU Conversion Kit Brochure DET-722
    EnbliGuard? TU Conversion Kit Supplemental Instructions DEH-3456
    EnbliGuard? TU Trip Unit Installation/Instruction Manual DEH-4567
    EnbliGuard? TU Test Set - GTUTK20 DEH-4568A
    GE AK-1-15, AK-1-25 GEH-6466
    GE AK-1-50 DEH-40027
    GE AK-15, AK, AKU-25, AKR-30S, AKRU-30S GEH-5967
    GE AKR-30,30H, AKRU-30, AKR-50, AKJ-50 Series GEH-5966
    GE AK-100, AK,U,T,S,SU,ST-50, AK-75 GEH-5965
    GE AKR-100, AKR-75, AKW-100 GEH-5964
    Westinghouse DB-15 GEH-6318
    Westinghouse DB-25, DBL-25 (225A), DB-50, DBL-50 GEH-6319
    Westinghouse DS-206, DSL-206, DS416, DSL-416, DS-420, DS-632 DEH-023
    Westinghouse DB-100 (4000A), DB-75 (3000A) GEH-6320
    ITE K-1600 (red), K, KDON-1600 Black, K-2000, K-225, K-600,
    KDON-600, K-800, KDON-800, KDON-1600 (red) GEH-6294
    ITE KC (1600A), KC (800A) GEH-6433
    ITE KA GEH-6293
    ITE KB (Metal), KB (Slate Drawout), KB (Slate Fixed) GEH-6295
    ITE K-3000, K-4000 DEH-133
    ITE KD-3000, KE-4000 DEH-40019
    Allis Chalmers LA, LAF - 1600 (BLUE), LA, LAF-600 (BLUE) DEH-40008
    Allis Chalmers LA, LAF - 1600 (GOLD), LA, LAF-600 (GOLD), LA, LAF-800,
    RL, RLX, RLE-1600 & 800 DEH-40009A
    Note: Conversion Kit Pricing tables are located on pages 2-14
    through 2-16.
    Switchgear
    2
    2-14 Aftermarket Catalog www.geelectrical.com Prices and data subject
    to change without notice
    Low Voltage Power and DC Circuit Breakers
    EnbliGuard? TU Trip Unit
    Conversion Kits Selection Guide
    For GE Power Circuit Breakers
    EnbliGuard? TU Trip Unit Conversion Kits for 3-Phase, 3-Wire, List Price, GO-104G
    LSI1 (04) LSIG1 (05) LSIGDA (09)
    Breaker Ammeter All Advanced Ammeter All Advanced Ammeter All Advanced
    Frame Amps Model Ammeter (A) + RELT (B) Options (C) Ammeter (A) + RELT (B) Options (C) Ammeter (A) + RELT (B) Options (C)
    225 AK115
    AKO15
    600 AK125 緯軒機電2520.00 緯軒機電2820.00 緯軒機電4920.00 緯軒機電3000.00 緯軒機電3300.00 緯軒機電5400.00 緯軒機電3620.00 緯軒機電3920.00 緯軒機電6020.00
    AKO25
    800 AKR30 緯軒機電2620.00 緯軒機電2920.00 緯軒機電5040.00 緯軒機電3100.00 緯軒機電3400.00 緯軒機電5520.00 緯軒機電3720.00 緯軒機電4020.00 緯軒機電6140.00
    AKR3S1 ———
    AK150
    1600 AKO50 緯軒機電2620.00 緯軒機電2920.00 緯軒機電5040.00 緯軒機電3100.00 緯軒機電3400.00 緯軒機電5520.00 緯軒機電3720.00 緯軒機電4020.00 緯軒機電6140.00
    AKR50
    AK150
    2000 AKO50
    AKR50
    3000 AKO75
    3200 AKR75 緯軒機電2720.00 緯軒機電3020.00 緯軒機電5140.00 緯軒機電3200.00 緯軒機電3500.00 緯軒機電5620.00 緯軒機電3820.00 緯軒機電4120.00 緯軒機電6240.00
    AKO10
    4000 AKR10
    AKW10
    1For AK30S breakers (AKR3S), LSH and LSHG List Pricing is the same as LSI and LSIG, respectively.
    For GE Power Circuit Breakers
    EnbliGuard? TU Trip Unit Conversion Kits for 3-Phase, 4-Wire, List Price, GO-104G
    LSI LSIG1 (04) LSIGDA (09)
    Breaker Ammeter All Advanced Ammeter All Advanced Ammeter All Advanced
    Frame Amps Model Ammeter (A) + RELT (B) Options (C) Ammeter (A) + RELT (B) Options (C) Ammeter (A) + RELT (B) Options (C)
    225 AK115
    AKO15
    600 AK125 — — — 緯軒機電3275.00 緯軒機電3575.00 緯軒機電5675.00 緯軒機電3895.00 緯軒機電4195.00 緯軒機電6295.00
    AKO25
    800 AKR30 — — — 緯軒機電3375.00 緯軒機電3675.00 緯軒機電5795.00 緯軒機電3995.00 緯軒機電4295.00 緯軒機電6415.00 AKR3S1
    AK150
    1600 AKO50 — — — 緯軒機電3375.00 緯軒機電3675.00 緯軒機電5795.00 緯軒機電3995.00 緯軒機電4295.00 緯軒機電6415.00
    AKR50
    AK150
    2000 AKO50
    AKR50
    3000 AKO75 — — — 緯軒機電3475.00 緯軒機電3775.00 緯軒機電5895.00 緯軒機電4095.00 緯軒機電4395.00 緯軒機電6515.00 3200 AKR75
    AKO10
    4000 AKR10
    AKW10
    1For AK30S breakers (AKR3S), LSH and LSHG List Pricing is the same as LSI and LSIG, respectively.
    For *Allis-Chalmers Power Circuit Breakers
    EnbliGuard? TU Trip Unit Conversion Kits for 3-Phase, 3-Wire, List Price, GO-104G
    LSI (04) LSIG (05) LSIGDA (09)
    Breaker2 Ammeter All Advanced Ammeter All Advanced Ammeter All Advanced
    Frame Amps Model Ammeter (A) + RELT (B) Options (C) Ammeter (A) + RELT (B) Options (C) Ammeter (A) + RELT (B) Options (C)
    600 ASL6B 緯軒機電2960.00 緯軒機電3260.00 緯軒機電5360.00 緯軒機電3440.00 緯軒機電3740.00 緯軒機電5840.00 緯軒機電4060.00 緯軒機電4360.00 緯軒機電6460.00 ASL6G
    800 ASL80
    ASR80
    ASL1B 緯軒機電3060.00 緯軒機電3360.00 緯軒機電5460.00 緯軒機電3540.00 緯軒機電3840.00 緯軒機電5940.00 緯軒機電4160.00 緯軒機電4460.00 緯軒機電6560.00
    1600 ASL1G
    ASR16
    2Contact Factory for Pricing and Availability on Breaker Models not listed.
    *Allis-Chalmers is a trademark of Allis-Chalmers Manufacturing Company Corporation.
    Pricing for EnbliGuard? TU are determined by the Frame Rating,
    Breaker Model, 3 or 4 wire, Trip Functions, and Advanced Features.
    (Example: Items highlighted in bold AKO25 C 3 F 06 04 A)
    Switchgear
    2
    Prices and data subject Aftermarket Catalog www.geelectrical.com 2-15
    to change without notice
    Low Voltage Power and DC Circuit Breakers
    EnbliGuard? TU Trip Unit
    Conversion Kits Selection Guide
    For *Allis-Chalmers Power Circuit Breakers
    EnbliGuard? TU Trip Unit Conversion Kits for 3-Phase, 4-Wire, List Price, GO-104G
    LSI LSIG (05) LSIGDA (09)
    Breaker2 Ammeter All Advanced Ammeter All Advanced Ammeter All Advanced
    Frame Amps Model Ammeter (A) + RELT (B) Options (C) Ammeter (A) + RELT (B) Options (C) Ammeter (A) + RELT (B) Options (C)
    600 ASL6B — — — 緯軒機電3715.00 緯軒機電4015.00 緯軒機電6115.00 緯軒機電4335.00 緯軒機電4635.00 緯軒機電6735.00 ASL6G
    800 ASL80
    ASR80
    ASL1B — — — 緯軒機電3815.00 緯軒機電4115.00 緯軒機電6215.00 緯軒機電4435.00 緯軒機電4735.00 緯軒機電6835.00
    1600 ASL1G
    ASR16
    For **I-T-E Power Circuit Breakers
    EnbliGuard? TU Trip Unit Conversion Kits for 3-Phase, 3-Wire, List Price, GO-104G
    LSI (04) LSIG (05) LSIGDA (09)
    Breaker2 Ammeter All Advanced Ammeter All Advanced Ammeter All Advanced
    Frame Amps Model Ammeter (A) + RELT (B) Options (C) Ammeter (A) + RELT (B) Options (C) Ammeter (A) + RELT (B) Options (C)
    225 AIKA2
    AIK22
    AIKBM
    AIKBS 緯軒機電2720.00 緯軒機電3020.00 緯軒機電5140.00 緯軒機電3200.00 緯軒機電3500.00 緯軒機電5620.00 緯軒機電3820.00 緯軒機電4120.00 緯軒機電6240.00
    600 AIKBX
    AIK60
    800 AIKC8
    AIK80
    AIKC1
    AIK16 緯軒機電2820.00 緯軒機電3120.00 緯軒機電5240.00 緯軒機電3300.00 緯軒機電3600.00 緯軒機電5720.00 緯軒機電3920.00 緯軒機電4220.00 緯軒機電6340.00
    1600 AIK1B
    AIKN1
    2000 AIK20 緯軒機電2920.00 緯軒機電3220.00 緯軒機電5340.00 緯軒機電3400.00 緯軒機電3700.00 緯軒機電5820.00 緯軒機電4020.00 緯軒機電4320.00 緯軒機電6440.00
    3000 AIK30 緯軒機電4120.00 緯軒機電4420.00 緯軒機電6540.00 緯軒機電4600.00 緯軒機電5100.00 緯軒機電7020.00 緯軒機電5220.00 緯軒機電5520.00 緯軒機電7640.00 4000 AIK40
    For **I-T-E Power Circuit Breakers
    EnbliGuard? TU Trip Unit Conversion Kits for 3-Phase, 4-Wire, List Price, GO-104G
    LSI LSIG (05) LSIGDA (09)
    Breaker2 Ammeter All Advanced Ammeter All Advanced Ammeter All Advanced
    Frame Amps Model Ammeter (A) + RELT (B) Options (C) Ammeter (A) + RELT (B) Options (C) Ammeter (A) + RELT (B) Options (C)
    225 AIKA2
    AIK22
    AIKBM
    600 AIKBS — — — 緯軒機電3475.00 緯軒機電3775.00 緯軒機電5895.00 緯軒機電4095.00 緯軒機電4395.00 緯軒機電6515.00
    AIKBX
    AIK60
    800 AIKC8
    AIK80
    AIKC1
    1600 AIK16 — — — 緯軒機電3575.00 緯軒機電3875.00 緯軒機電5995.00 緯軒機電4195.00 緯軒機電4495.00 緯軒機電6615.00
    AIK1B
    AIKN1
    2000 AIK20 — — — 緯軒機電3675.00 緯軒機電3975.00 緯軒機電6095.00 緯軒機電4295.00 緯軒機電4595.00 緯軒機電6715.00
    3000 AIK30
    4000 AIKE4 — — — 緯軒機電4875.00 緯軒機電5375.00 緯軒機電7295.00 緯軒機電5495.00 緯軒機電5795.00 緯軒機電7915.00
    AIK40
    2Contact Factory for Pricing and Availability on Breaker Models not listed.
    *Allis-Chalmers is a trademark of Allis-Chalmers Manufacturing Company Corporation.
    **I-T-E is a registered trademark of Siemens Energy and Automation, Inc.
    Switchgear
    2
    2-16 Aftermarket Catalog www.geelectrical.com Prices and data subject
    to change without notice
    Low Voltage Power and DC Circuit Breakers
    EnbliGuard? TU Trip Unit
    Conversion Kits Selection Guide
    For *Westinghouse Power Circuit Breakers
    EnbliGuard? TU Trip Unit Conversion Kits for 3-Phase, 3-Wire, List Price, GO-104
    LSI (04) LSIG (05) LSIGDA (09)
    Breaker1 Ammeter All Advanced Ammeter All Advanced Ammeter All Advanced
    Frame Amps Model Ammeter (A) + RELT (B) Options (C) Ammeter (A) + RELT (B) Options (C) Ammeter (A) + RELT (B) Options (C)
    225 ADB15 緯軒機電2520.00 緯軒機電2820.00 緯軒機電4920.00 緯軒機電3000.00 緯軒機電3300.00 緯軒機電5400.00 緯軒機電3620.00 緯軒機電3920.00 緯軒機電6020.00 600 ADB25
    800 ADS06
    1600 ADB50 緯軒機電3060.00 緯軒機電3360.00 緯軒機電5460.00 緯軒機電3540.00 緯軒機電3840.00 緯軒機電5940.00 緯軒機電4160.00 緯軒機電4460.00 緯軒機電6560.00
    ADS16
    2000 ADS20
    3000 ADB75 緯軒機電3260.00 緯軒機電3560.00 緯軒機電5660.00 緯軒機電3740.00 緯軒機電4040.00 緯軒機電6140.00 緯軒機電4360.00 緯軒機電4660.00 緯軒機電6760.00 3200 ADS32
    4000 ADB10
    For *Westinghouse Power Circuit Breakers
    EnbliGuard? TU Trip Unit Conversion Kits for 3-Phase, 4-Wire, List Price, GO-104G
    LSI LSIG (05) LSIGDA (09)
    Breaker1 Ammeter All Advanced Ammeter All Advanced Ammeter All Advanced
    Frame Amps Model Ammeter (A) + RELT (B) Options (C) Ammeter (A) + RELT (B) Options (C) Ammeter (A) + RELT (B) Options (C)
    225 ADB15 — — — 緯軒機電3275.00 緯軒機電3575.00 緯軒機電5675.00 緯軒機電3895.00 緯軒機電4195.00 緯軒機電6295.00 600 ADB25
    800 ADS06
    1600 ADB50 — — — 緯軒機電3815.00 緯軒機電4115.00 緯軒機電6215.00 緯軒機電4435.00 緯軒機電4735.00 緯軒機電6835.00
    ADS16
    2000 ADS20
    3000 ADB75 — — — 緯軒機電4015.00 緯軒機電4315.00 緯軒機電6415.00 緯軒機電4635.00 緯軒機電4935.00 緯軒機電7035.00 3200 ADS32
    4000 ADB10
    1Contact Factory for Pricing and Availability on Breaker Models not listed.
    *Westinghouse is a trademark of Westinghouse Electric Corporation.
    EnbliGuard? TU Trip Rating Plug Specifications
    May Be Used With
    Trip Plug Plug Minimum Maximum List Price
    Product Number Rating Sensor Sensor GO-329R
    GTP0060U0101 60A2 150A4 150A4 緯軒機電130.00
    GTP0080U0101 80A2 150A4 150A5 緯軒機電130.00
    GTP0100U0103 100A3 150A4 225A5 緯軒機電130.00
    GTP0125U0103 125A2 150A4 225A5 緯軒機電130.00
    GTP0150U0104 150A 150A4 400A 緯軒機電130.00
    GTP0200U0204 200A 200A5 400A 緯軒機電130.00
    GTP0225U0306 225A 225A 600A 緯軒機電130.00
    GTP0250U0407 250A 400A 630A6 緯軒機電130.00
    GTP0300U0408 300A 400A 800A 緯軒機電130.00
    GTP0350U0408 350A 400A 800A 緯軒機電130.00
    GTP0400U0410 400A 400A 1000A 緯軒機電130.00
    GTP0450U0612 450A 600A 1200A 緯軒機電130.00
    GTP0500U0613 500A 600A 1250A6 緯軒機電130.00
    GTP0600U0616 600A 600A 1600A 緯軒機電130.00
    GTP0700U0816 700A 800A 1600A 緯軒機電130.00
    GTP0750U0820 750A 800A 2000A 緯軒機電130.00
    GTP0800U0820 800A 800A 2000A 緯軒機電130.00
    GTP0900U1020 900A 1000A 2000A 緯軒機電130.00
    GTP1000U1025 1000A 1000A 2500A 緯軒機電130.00
    GTP1100U1225 1100A 1200A 2500A 緯軒機電130.00
    GTP1200U1232 1200A 1200A 3200A 緯軒機電130.00
    GTP1500U1640 1500A 1600A 4000A 緯軒機電130.00
    GTP1600U1640 1600A 1600A 4000A 緯軒機電130.00
    GTP1900U2050 1900A 2000A 5000A 緯軒機電130.00
    GTP2000U2050 2000A 2000A 5000A 緯軒機電130.00
    GTP2200U2550 2200A 2500A 5000A 緯軒機電130.00
    GTP2400U2564 2400A 2500A 6400A6 緯軒機電130.00
    GTP2500U2564 2500A 2500A 6400A6 緯軒機電130.00
    GTP3000U3064 3000A 3000A 6400A6 緯軒機電130.00
    GTP3200U3264 3200A 3200A 6400A6 緯軒機電130.00
    GTP3600U4064 3600A 4000A 6400A6 緯軒機電130.00
    GTP4000U4064 4000A 4000A 6400A6 緯軒機電130.00
    GTP5000U5064 5000A 5000A 6400A6 緯軒機電130.00
    GTP6000U6064 6000A 6000A 6400A6 緯軒機電130.00
    2WavePro and AKR only. EnbliGuard? G min. trip plug is 150A.
    3PowerBreak only. EnbliGuard? G min. trip plug is 150A.
    4WavePro and AKR only. EnbliGuard? G min. sensor is 400A.
    5PowerBreak only. EnbliGuard? G min. sensor is 400A.
    6IEC only sensor, UL equivalents are 600A.
    Switchgear
    2
    Prices and data subject Aftermarket Catalog www.geelectrical.com 2-17
    to change without notice
    Low Voltage Power and DC Circuit Breakers
    EnbliGuard? TU Trip Unit
    Conversion Kit Accessories and Hardware
    Conversion Kit Accessories and Hardware
    Debion Product Number List Price GO Schedule
    4 wire RELT & Ground Fault Alarm Harness kit. Used to add RELT or Ground Fault Alarm to an existing MVT
    installation in combination with an EnbliGuard? TU. Harness comes with Breaker and Cubicle side, 8 feet
    of wire, terminal block, and RELT Labels1 GTURHA 緯軒機電150.00 GO-104G
    4 wire RELT & Ground Fault Alarm Harness kit. Used to add RELT or Ground Fault Alarm to an existing MVT
    installation in combination with an EnbliGuard? TU. Harness comes with Breaker and Cubicle side, 8 feet of
    wire, terminal block, and RELT Labels. Includes 9 Pin Harness for 24VDC, Communications, and Voltage Source. GTURHB 緯軒機電200.00 GO-104G
    RELT Switch Kit: Includes the following: RELT Switch, Lockable cover, contacts, wire harness, warning labels GTURSK 緯軒機電485.00 GO-104G
    Zone Selective Interlock Module TIM1 緯軒機電402.00 GO-245B
    Power Leader Voltage Conditioners – Supplies isolated bus voltage signal to EnbliGuard? TU trip units PLVC1G01 緯軒機電200.00/set GO-104A
    Power Leader Power Supply 1.5A power supply. Qty 15 trip units may be powered from a single power supply PLPS4G01 緯軒機電1250.00 GO-104A
    GE Portable Test Kit – Used for testing phase currents, Ground Fault, disabling Ground fault, RELT, Trip Breaker GTUTK20 緯軒機電3000.00 GO-245B
    Rating Plug Removal Tool TRTOOL 緯軒機電12.00 GO-135S
    Set-up Software GTUSS 緯軒機電200.00 GO-329R
    1RELT and Ground Fault Alarm require 24VDC. If 24VDC cable is required order GTURHB
    EnbliGuard? TU Trip Units are compatible with MicroVersaTrip?, RMS9, EPIC RMS9, MicroVersaTrip? Plus and PM,
    Enhanced MicroVersaTrip? Plus and PM Trip Units models.
    Coming Soon:
    Power Break? II in a Power Break? I (fixed and drawout)
    EnbliGuard? G in AKD-5, AKD-6, AKD-8 switchgear line-ups
    Contact factory for availability and options
    Switchgear
    2
    2-18 Aftermarket Catalog www.geelectrical.com Prices and data subject
    to change without notice
    Low Voltage Power and DC Circuit Breakers Trip Unit
    Accessories
    Optional Remote Display—Features
    —Provides safe, convenient closed-door access to breaker
    metering, status and setup functions
    —Available for use with either MicroVersaTrip? Plus or
    MicroVersaTrip? PM trip units
    —Rugged plastic NEMA Type 1 enclosure with LCD and keypad
    —Mounts easily on outside of breaker compartment door
    —Sealable, b LEXAN protective cover over display and "Enter"
    key prohibits unauthorized trip setting changes
    —Connects to breaker trip unit via 20-pin plug-in cable for fast
    installation
    —Breaker trip unit operates independently if cable is disconnected
    Optional Remote Display
    Target Module
    GE Trip Unit Portable Test Set
    Optional Remote Display (for MicroVersaTrip?)
    List Price
    Accessory Type Product Number GO-104B
    Remote Display w/ 6’ Cable REMDIS1 緯軒機電350.00
    Replacement Cable REMDIS2 緯軒機電35.00
    Target Module (for ProTrip?)
    All ProTrip? conversion kits come with a target module.
    Order another only for renewal purposes.
    List Price
    Product Number GO-104P
    TARGET02P 緯軒機電285.00
    GE Trip Unit Portable Test Set (for MicroVersaTrip? and ProTrip?)
    Allows for self-tests and functioning trip/no trip tests. Operates on
    batteries (not included) or 120 VAC source.
    List Price
    Product Number GO-245B
    TVRMS2 緯軒機電3000.00
    EnbliGuard? TU Test Set
    Allows for self-tests and functioning trip/no trip tests. Operates on
    batteries (not included) or 120 VAC source.
    List Price
    Product Number GO-245B
    GTUTK20 緯軒機電3000.00
    EnbliGuard? TU Test Set
    Switchgear
    2
    Prices and data subject Aftermarket Catalog www.geelectrical.com 2-19
    to change without notice
    Low Voltage Power and DC Circuit Breakers Trip Unit
    Accessories
    POWER LEADER? Power Supply
    The POWER LEADER? power supply provides 24Vdc control power to MicroVersaTrip? PM trips units used on WavePro low voltage
    power circuit breakers. The control power is required for the trip unit’s communication and protective relay functions.
    List Price System Requirements
    Debion Product Number GO-104A (Not included with power supply)
    1.5A power supply. PLPS4G01 緯軒機電1250.00 Input power, 100VA
    Maximum wire length from power supply (85-265 Vac or 100-370 Vdc)
    to trip device is 100 feet. A maximum of 45 trip
    units may be powered from a single power supply.
    POWER LEADER? Voltage Conditioner
    Conditions and scales 120Vac to 1.76Vac for use by the trip unit for voltage sensing. Provides transient protection. Requires isolation
    PTs with 120 volt secondary. Supports up to 15 trip units at a maximum distance of 20 feet. Required for PM trip units only.
    List Price System Requirements
    Debion Product Number GO-104A (Not included with voltage conditioners)
    Supplies isolated bus voltage signal PLVC1G01 緯軒機電200.00/set One set of 3 voltage conditioners required
    to MicroVersaTrip? PM trip units. for each sensing b. PTs also required.
    MicroVersaTrip? Portable Power Pack
    The MicroVersaTrip? Portable Battery Pack is a maintenance power source used to power up trip units for setting or adjusting trip set
    points or for reading trip targets when the trip unit is not otherwise energized. It is a redundant power source to the onboard battery
    supplied with the Enhanced MicroVersaTrip? Plus and PM (5-button keypad) trip units. The portable battery pack connects to the trip
    unit through the rating plug test jack. It requires three (3) standard 9Vdc alkaline batteries (not included).
    List Price
    Debion Product Number GO-245A
    MicroVersaTrip? Portable Power Pack TVPBP 緯軒機電75.00
    MicroVersaTrip? and EnbliGuard? Rating Plug Removal Tool
    List Price
    Debion Product Number GO-135S
    MicroVersaTrip? and EnbliGuard? Rating Plug Removal Tool TRTOOL 緯軒機電12.00
    Switchgear
    2
    2-20 Aftermarket Catalog www.geelectrical.com Prices and data subject
    to change without notice
    Low Voltage Power and DC Circuit Breakers
    Electrically Operated Racking Device
    The electrically operated racking device allows maintenance
     personnel the ability to be up to 30 feet away from a draw-out
    breaker during the racking operation. This was typically only an
    option with medium voltage switchgear. Now, GE offers this as an
    option with low voltage switchgear.
    The electric motor is operated using convenient 115V AC power
    with a plug-in power cord. The gearbox is easily attached to the
    front of the breaker with a sliding latch connection.
    The low voltage racking devices can be used with any WavePro or
    EnbliGuard? breaker. Large frame WavePro breakers (3200 Amp
    and above)1 require an accessory kit and a retrofit door to
    accommodate the device.
    Allowing the user to be physically removed from the breaker
     racking mechanics during operation provides a peace of mind
    not usually available in a low voltage application.
    1Manufactured before 9/1/05.
    Easy and Safe Operation
    PRESS!
    A push of the button on a handheld
    remote operator draws the breaker out
    with a 115V AC motor in the gear box.
    PRESS!
    Another push of the button racks the
    breaker back into place.
    Switchgear
    2
    Prices and data subject Aftermarket Catalog www.geelectrical.com 2-21
    to change without notice
    Low Voltage Power and DC Circuit Breakers
    Electrically Operated Racking Device
    Technical Specifications
    Remote operation through a cable-connected handheld control
    —Permits control of gearbox and racking motor from remote
     b, allowing the user to be remote from the breaker during
    the racking procedure.
    —Cable allows user to be up to 30 feet away from the breaker
    and away from the arc flash center.
    —Allows user to determine their b based on room layout.
    —Simple start switch push button in handheld box.
    Portable gearbox with full operator control
    —Allows the user to easily move a draw-out circuit breaker
    between CONNECT and DISCONNECT bs.
    —Can be used with WavePro or EnbliGuard? breakers in
    Enblisys?, AKD-10 or Power Break? switchboard line-ups (with
    WavePro breakers).
    —Motor directional switch for IN/OUT racking control.
    —Circuit breaker reset toggle switch for control power.
    Racking Device
    —Electrically powered with 115V AC power (4 foot cord).
    —Sliding latch allowing device to be easily attached to front of
    breakers (WavePro or EnbliGuard?).
    Retrofits (Product shipped before June 2005)
    —Small Frame (800 - 2000 Amp) WavePro breakers accept the
    Racking Device without modification.
    —Existing Large Frame (3200 - 5000 Amp) WavePro breakers
    compatible by simply replacing the cubicle door.
    —All EnbliGuard? breakers accept the Racking Device without
    modifications.
    Racking Devices
    Product Number Debion
    WPEGRRLV Remote Racking Device
    WPEGRRMODL Large Frame Breaker
在線詢盤/留言
  • 免責聲明:以上所展示的信息由企業(yè)自行提供,內(nèi)容的真實性、準確性和合法性由發(fā)布企業(yè)負責,本網(wǎng)對此不承擔任何保證責任。我們原則 上建議您選擇本網(wǎng)高級會員或VIP會員。
    0571-87774297